How to Connect the Manipulator and M/C Cable

  1. Loosen two of the M4 hexagon socket head cap bolts.
    The bolts cannot be removed.

  2. Pull the pull rod towards you and slide it to the left.

  3. Connect the connector and the M/C cable at five locations so that the orientation of the sheet metal aligns with the symbol.

  4. Slide the pull rod to the right and push it in.

  5. Secure two of the M4 hexagon socket head cap bolts.

    • Tightening Torque: 2.0 ± 0.2 N·m

    KEY POINTS


    Be careful not to tighten the screw while the cable is pinched.

  6. Arrange the following based on the environmental specifications:

    For Standard and Cleanroom model:

    Adjust so that the mark align, secure four of the M3 hexagon socket head cap bolts.

    • Tightening Torque: 2.0 ± 0.1 N·m

    KEY POINTS


    Be careful not to tighten the screw while the cable is pinched.

    For Protected-Models:

    Fit the spacer into the packing seal.

    Adjust so that the mark align, insert the seal washer, and secure it with four M3 hexagon socket head cap bolt.

    • Tightening Torque: 2.0 ± 0.1N·m

    KEY POINTS


    Be careful not to tighten the screw while the cable is pinched.