Power Connection

CAUTION


  • Before supplying power to the part feeder, make sure that the distribution voltage is the same as the nominal voltage.
  • Never disconnect the power cable when the unit is on. Always turn the machine off before disconnecting the power cable.
  • Use PELV (protected extra-low voltage) nominal voltage.
  • Unplug the main power plug when plugging / unplugging cords.

Power Connection

Pin Signal description Cable
(1) 24VDC PELV S-Power L+
(2) 0V GND S-Power L-
(3) EARTH PE
(11) 24VDC PELV Power Black
(12) 0V GND Power White
(13) – (14) Not used

Connector type of IF-530 side: M16, 5 poles, male

Characteristic Value
Voltage +24VDC ±5%
Power Current 6A
S-Power Current 14A

KEY POINTS


S-Power is the safety power for the backlight. Cutting this S-Power ensures that the backlight stays off. (e.g. to avoid danger from an infrared backlight)

The following connection schematics show how to connect the IF-240 depending on whether your application uses an external relay to ensure that the backlight is safely switched off. In either case, both “Power” and “S-Power” must be supplied when using the backlight.

Symbols Meaning
a Power connection without safety relay
b Power connection with safety relay

KEY POINTS


Both Power and S-Power can be connected to a single power supply or to two different power supplies.