Starting a Function
- Before a function can be started, the reset signal (ExtCmdReset) must be High.
- A command request can be received when the command set input (ExtCmdSet) is changed from Low to High while the reset input (ExtCmdReset) is set to High.
- When the command set input (ExtCmdSet) is set to High while the reset input is in Low state, the request will be ignored.
- When the reset input (ExtCmdSet) is changed to High while the command set input (ExtCmdSet) is set to High, the Controller cannot recognize the signal as a command request.
CAUTION
Release of the reset input should be executed after the Controller becomes operable. Also, initialize each input when the Controller is reset.