Power Cable
You must provide a power cable. Be sure to use the specifications below.
Symbol | Item | Specifications |
---|---|---|
a | Plug | Comply with local safety regulation
|
b | Flexible cable | Comply with IEC/EN standards or local safety regulation Example:
|
c | Appliance coupler | Comply with IEC/EN standards or local safety regulation
|
For Japan
Item | Specifications |
---|---|
Plug | PSE Certified Class I (2P+PE), AC125 V, 7 A or higher |
Code | PSE Certified 0.75 mm2 or more |
Connector | PSE Certified IEC 60320-1 Standard Sheet C13: AC125 V/10 A or higher |
Precautions for use
CAUTION
Operating the Manipulator without a brake release unit or external short connector connected may cause the brake to fail to release, possibly damaging the brake.
After using the brake release unit, be sure to connect the external short circuit connector to the Manipulator or make sure to leave the connector for the brake release unit connected.
Keep the external short connector. Otherwise you cannot release the brakes.
If you turn on the brake release unit while the brake release switch is being pressed, an unintended arm may move downward. Before turning on the brake release unit, make sure that the brake release switch is not pressed.
If you turn on the brake release unit without the connector, it may lead to the short for the male pin used in the connector. Before turning on the brake release unit, make sure that the connector is connected.