Power Connection

CAUTION


  • Before supplying power to the part feeder, make sure that the distribution voltage is the same as the nominal voltage.
  • Never disconnect the power cable when the unit is on. Always turn the machine off before disconnecting the power cable.
  • Use PELV (protected extra-low voltage) nominal voltage.
  • Unplug the main power plug when plugging / unplugging cords.

Power Connection

Pin Signal description Cable
(1) 24VDC PELV S-Power 1
(2) 0V GND S-Power 2
(3) 24VDC PELV Power 3
(4) 0V GND Power 4
(5) EARTH PE

Connector type (on IF-240 side): M16, 5 Poles, male

When all functions are working simultaneously (vibration, backlight, and outputs), the required current increases to 8A.

Characteristic Value
Voltage +24VDC +5%/-0%
Power Current 5A
S-Power Current 3A

KEY POINTS


  • The backlight receives its power supply from S-Power. Cutting this S-Power ensures that the backlight stays off. (e.g. to avoid danger from an IR backlight).
  • When operating the feeder, connect both Power and S-Power to the power supply.

The following connection schematics show how to connect the IF-240 depending on whether your application uses an external relay to ensure that the backlight is safely switched off.

Symbols Meaning
a Power connection without safety relay
b Power connection with safety relay

KEY POINTS


Both Power and S-Power can be connected to a single power supply or to two different power supplies.

Short-circuit current rating:

SCCR
Power 40A
S-Power 40A