Power Connection
CAUTION
- Before supplying power to the part feeder, make sure that the distribution voltage is the same as the nominal voltage.
- Never disconnect the power cable when the unit is on. Always turn the machine off before disconnecting the power cable.
- Use PELV (protected extra-low voltage) nominal voltage.
- Unplug the main power plug when plugging / unplugging cords.
Power Connection
| Pin | Signal description | Cable |
|---|---|---|
| (1) | 24VDC PELV S-Power | 1 |
| (2) | 0V GND S-Power | 2 |
| (3) | 24VDC PELV Power | 3 |
| (4) | 0V GND Power | 4 |
| (5) | EARTH | PE |
Connector type (on IF-240 side): M16, 5 Poles, male
When all functions are working simultaneously (vibration, backlight, and outputs), the required current increases to 8A.
| Characteristic | Value |
|---|---|
| Voltage | +24VDC +5%/-0% |
| Power Current | 5A |
| S-Power Current | 3A |
KEY POINTS
- The backlight receives its power supply from S-Power. Cutting this S-Power ensures that the backlight stays off. (e.g. to avoid danger from an IR backlight).
- When operating the feeder, connect both Power and S-Power to the power supply.
The following connection schematics show how to connect the IF-240 depending on whether your application uses an external relay to ensure that the backlight is safely switched off.
| Symbols | Meaning |
|---|---|
| a | Power connection without safety relay |
| b | Power connection with safety relay |
KEY POINTS
Both Power and S-Power can be connected to a single power supply or to two different power supplies.
Short-circuit current rating:
| SCCR | |
|---|---|
| Power | 40A |
| S-Power | 40A |