Overview
The IF-240 is a standalone module with its own controller. Its power supply is located on the rear panel of the product.
Electrical interfaces of the IF-240
| Symbols | Meaning |
|---|---|
| a | Power connection |
| b | Ethernet connection (RJ45) |
| c | - |
| d | - |
| e | Either the digital input for the hopper (2nd unit) or the purge gate (exclusive use) |
| f | Output 1 for Hoppers |
| g | Either the digital output for the hopper (2nd unit) or the purge gate (exclusive use) |
KEY POINTS
If you install a purge gate, you can only connect one hopper.
If you install a purge gate, connect it to (g) and the hopper to (f).
For information on installing the purge actuator kit, refer to the following: