Outer Dimension of Purging Platform

Material
L Stainless steel
M Stainless steel
N

POM (Refer to the following:)

Plate (series: IF-240)

CAUTION


To use the purge actuator kit, plug the cable in the feeder "IN2" / "OUT2" outputs.

Do not unplug the cable unless you are removing the purge actuator kit.

KEY POINTS


When plugging in the purge platform, the motor will seek its origin position, emitting some noise. That noise may be heard while operating too, under certain circumstances.

CAUTION


To prevent the motor from being prematurely damaged, make sure all movements are aimed at emptying the platform.

(e.g. consider a purging system with the flap on the left. Only the "Left" vibration may be used. Similarly, with a purging system whose flap is on the right, only the "Right" vibration may be used).