Replacing the Purging Actuator

CAUTION


Before replacing the actuator, unplug the purging frame from the feeder and remove it. (Four hand-tightened screws)

  1. Remove the protective cover.

    4 screws Tx10

Symbols Meaning
a Protective cover
  1. Cut the zip-tie, taking care not to damage the cables.

  2. Unscrew the actuator block.

    3 screws Tx10

    Remove the actuator (1) and pull on the connector (2), not the cable itself, to disconnect it from the actuator.

Symbols Meaning
a Actuator
  1. Remove the retaining ring.

    Swap out the actuator block.

    Reattach the retaining ring.

Symbols Meaning
a Retaining ring
b Actuator
  1. Plug in the actuator block (1).

    Tighten the flap screw (2). (hold the flap in the closed position while screwing in)

    Screw in the bracket (3) with the flap still in held in the closed position.

    3 screws Tx 10, Tightening torque 1.2Nm

Symbols Meaning
a Actuator
  1. Tie the cables together with a zip-tie.

  2. Screw the protective cover back into position.

    4 screws Tx 10, Tightening torque 0.6 Nm

Symbols Meaning