Table of Mechanical Specifications

Table of Mechanical Specifications

Item IF-A1520 IF-A2330 Notes
Machine name Flexible feeder
Product size 330 × 172 × 129 mm 480 × 292 × 249 mm See below.
Outer Dimensions
Product mass 9 kg 27 kg
Recommended part size Length of long side 5 to 40 mm Length of long side 15 to 60 mm *1
Recommended part weight ≦2 g *1
Range of vibration frequency variation

20 Hz to 80 Hz

(1 Hz steps)

15 Hz to 35 Hz

(1 Hz steps)

Picking area 195 × 150 mm 300 × 230 mm See below.
Picking Area
Fixing screw size M6 M8 See below.
Mounting Hole Positions
Maximum Permissible External Force

Fx: 10 N

Fy: 10 N

Fz: 20 N

Fx: 10 N

Fy: 10 N

Fz: 30 N

See below.
Maximum Permissible External Force
Maximum load weight (parts) 0.4 kg 1.5 kg
Maximum platform weight 1.35 kg 4 kg *2
Maximum Plate Displacement

X direction: ±1.5 mm

Y direction: ±2 mm

Z direction: ±1 mm

X direction: ±8 mm

Y direction: ±10 mm

Z direction: ±3 mm

See below.
Maximum Plate Displacement
Repeatability in plate Z direction ≦0.02 mm ≦0.4 mm
Noise level <76 dB(A) <80 dB(A) *3

*1. Before use, operate the flexible feeder to feed actual parts, and make the checks below. Parts that cannot achieve these are not suitable for flexible feeders.

  • The parts disperse.
  • The parts move.
  • The overlapping of parts has been eliminated.

*2. This is the mass limit for customers customizing the platform. Note that this limit is the total mass of the platform and payload.

CAUTION


The customer is responsible for customizing the platform.
If you wish to modify the platform, remove it from the main unit by following the instructions below.

Attaching/Removing Platform

*3. The conditions for noise measurements are shown below.

  • No parts loaded on the platform
  • Equivalent noise level (LAeq) measured at a distance of 1000 mm from the product

CAUTION


The noise level may be high due to parts vibrating on the platform. In this case, the customer or system integrator is responsible for implementing any measures necessary to meet the operator’s safety requirements.