Power Supply

CAUTION


Make the checks below before supplying power to the flexible feeder.

  • Ensure that the distribution voltage used is the same as the specified supply voltage.
  • Use a PELV (Protected Extra Low Voltage) circuit to supply the voltage.
  • Make sure that the plug connected to the 24 VDC interface has the correct polarity.
  • Do not connect the IF-80 and IF-240 power cables to the IF-A1520 and IF-A2330 power connectors.

KEY POINTS


  • Connect both Power and S-Power to the power supply when operating the flexible feeder. Both Power and S-Power can be connected to a single power supply or to two different power supplies.
  • You are recommended to provide a dedicated power source for each flexible feeder.
  • Operation has been confirmed with the following power supplies.
    • PULS QS20.241
    • SIEMENS 6EP1336-3BA10
    • OMRON S8VK-S48024

Pin Name Description
1 Power 24V Main power supply (24 VDC)
2 Power 0V Main power supply (GND)
3 S-Power 24V Backlight power supply (24 VDC)
4 S-Power 0V Backlight power supply (GND)
5 PE EARTH

Connector on flexible feeder: Standard M16, 5 poles (male)

IF-A1520 IF-A2330
Power Voltage 24 VDC ±5% 24 VDC ±5%
Rated current 6 A 6A
S-Power Voltage 24 VDC ±5% 24 VDC ±5%
Rated current 2 A 3A