Power Supply
CAUTION
Make the checks below before supplying power to the flexible feeder.
- Ensure that the distribution voltage used is the same as the specified supply voltage.
- Use a PELV (Protected Extra Low Voltage) circuit to supply the voltage.
- Make sure that the plug connected to the 24 VDC interface has the correct polarity.
- Do not connect the IF-80 and IF-240 power cables to the IF-A1520 and IF-A2330 power connectors.
KEY POINTS
- Connect both Power and S-Power to the power supply when operating the flexible feeder. Both Power and S-Power can be connected to a single power supply or to two different power supplies.
- You are recommended to provide a dedicated power source for each flexible feeder.
- Operation has been confirmed with the following power supplies.
- PULS QS20.241
- SIEMENS 6EP1336-3BA10
- OMRON S8VK-S48024
| Pin | Name | Description |
|---|---|---|
| 1 | Power 24V | Main power supply (24 VDC) |
| 2 | Power 0V | Main power supply (GND) |
| 3 | S-Power 24V | Backlight power supply (24 VDC) |
| 4 | S-Power 0V | Backlight power supply (GND) |
| 5 | PE | EARTH |
Connector on flexible feeder: Standard M16, 5 poles (male)
| IF-A1520 | IF-A2330 | ||
|---|---|---|---|
| Power | Voltage | 24 VDC ±5% | 24 VDC ±5% |
| Rated current | 6 A | 6A | |
| S-Power | Voltage | 24 VDC ±5% | 24 VDC ±5% |
| Rated current | 2 A | 3A | |