Communication Cable (RS-232C)
Communication cables must be provided by the customer.
Connector Name | Standard |
---|---|
RS-232C connector (Controller side) | D-Sub 9-pin male Mating screw lock part #4 - 40 |
KEY POINTS
Use twisted pair shielded wires for cables.
The shield should be clamped to the hood for noise reduction.
The pin assignment of the RS-232C connector is shown in the following table.
Pin Number | Signal | Function | Signal Direction |
---|---|---|---|
1 | DCD | Carrier send | Inputs |
2 | RXD | Received data | Inputs |
3 | TXD | Transmitted data | Outputs |
4 | DTR | Data terminal ready | Outputs |
5 | GND | Signal ground | - |
6 | DSR | Data set ready | Inputs |
7 | RTS | Request to send | Outputs |
8 | CTS | Permission to send | Inputs |
9 | RI | Ring indicator | Inputs |