I/O Remote Settings

This section describes the functions and timing of the input/output signals.
By assigning remote functions to Standard I/O, Expansion I/O, and Fieldbus I/O, the robot system can be controlled from user-provided operating devices or sequencers.
By default, remote functions are assigned to the I/O of input numbers 0 to 7 and output numbers 0 to 8.
To be able to accept remote input from an external source, the control device must be set to remote in addition to assigning the remote function.
The I/O numbers where remote functions are assigned can be changed by the user.
For the setting procedure, refer to the following manual or online help.
"Epson RC+ User's Guide - Remote Control"

CAUTION


  • When using I/O with remote settings, pay attention to the following points. Using I/O with remote settings without satisfying the requirements may lead to system failure or safety issues.

    • This signal is not a safety signal. Do not use it for safety-related functions.
    • When making settings, do not make a mistake in the relationship between function assignments and wiring.
    • Be sure to check the correspondence between the functions and wiring before supplying power.
    • When checking operation, try to anticipate configuration or wiring errors. If the Manipulator performs an abnormal operation due to a setting or wiring error, do not hesitate to immediately stop Manipulator operation by pressing the emergency stop switch or by other means.

KEY POINTS


  • The remote function is enabled even when virtual I/O mode is enabled.

  • When making the remote settings for the I/O, make a record of the settings or save them as file data.

  • When remote functions are assigned to Fieldbus I/O, their responsiveness varies depending on the communication speed of the fieldbus. For details on the responsiveness of fieldbus, refer to the following manual.

    "Robot Controller Option Fieldbus I/O"