Before Use

CAUTION


  • Regarding the necessity for organizational measures for cyber security

    Organizational measures like those described below should be taken to address cybersecurity risks:

    • Perform risk analysis based on security threats and vulnerabilities related to your organization's assets.
    • Establish a security policy to address risks and educate and train appropriate personnel.
    • Establish guidelines for how to respond when security issues arise and make them known throughout your organization.
  • Security measures for network connections

    Epson robot systems are designed to be used within a closed local area network. Please refrain from connecting to networks with Internet access. If a connection to the Internet is required, please implement the necessary technical measures* to protect from malicious attacks and vulnerabilities over the Internet.

    *These measures include, but are not limited to, access controls, firewalls, data diodes, and so on.

KEY POINTS


  • Do not connect the following devices to the TP port of RC800-A. The different signal arrangement could cause a breakdown in the device.

    • Dummy plug (optional device)
    • Operation Pendant OP500
    • Operator Pendant OP500RC
    • Jog Pad JP500
    • Teaching Pendant TP-3
    • Operator Panel OP1
    • Teach Pendant TP1
  • For RC800-A, be sure to install Epson RC+ to the development PC first, and then connect the development PC and RC800-A with the USB cable.
    If RC800-A and the development PC are connected without installing Epson RC+ to the development PC, the [Add New Hardware Wizard] appears. If this wizard appears, click the [Cancel] button.

  • Security measures for USB memory devices
    Make sure that any USB memory device that will be connected to the Controller is not infected with a virus.