RS-232C Software Configuration

To configure a Windows Part RS-232C port

  1. The [System Configuration] command opens a dialog that contains several pages that are used to configure the system for the Epson RC+ 8.0 environment.

  2. Select [Controller]-[RS-232]-[PC].

  3. Set the [Enabled] check box.

  4. Change the settings as desired.

  5. Click the [Apply] button. The new settings are saved.

  6. Click the [Close] button.

KEY POINTS


If several ports are used for communication at one time with more than a 19200 baud rate, error 2929 or 2922 may occur. In this case, select a lower baud rate or avoid using several ports at one time.

To configure a standard / option RS-232C port

  1. The [System Configuration] command opens a dialog that contains several pages that are used to configure the system for the Epson RC+ 8.0 environment.

  2. Select [Controller]-[RS-232]-[CU].

  3. Select a port to configure.

  4. Change the settings as desired.

  5. Click the [Apply] button. The new settings are saved.

  6. Click the [Close] button.