Errors displayed in error dialog

Message Reason Remedy
Controller FW Version does not support OPC UA. The FW version of your Controller is not supported OPC UA. Refer to the following and update the firmware.

Operating Condition

Cannot connect with the controller because the task is running. Controller is working on a task, so Controller and OPC UA Configurator cannot be connected with Program mode. Wait for process of the task then connect.
The file format is invalid. The file format importing from PC is different from the file format selected in the application. Change the file format to specified format.
The file name is incorrect.

You are using letters other than half-width alphanumeric characters or underscore for the file name.

File mane is not specified name.

Change the file name.

Enter with half-width alphanumeric characters.

Attempted to import more than the file limit. You’ve tried to import files more than maximum number of files that can be imported.

Delete a file you already imported.

Reduce the number of files to import.

No files found to import. There is no file to import in the folder of import source. Place a file with the specified name in the folder of the PC of import source.
Parameter Error Full-width alphanumeric character or symbol are entered in setting for CSR or Self signed Certificate. Re-enter the correct value.
You tried to import a certificate that is not paired with the CSR. CSR saved in the Controller and Certificate to import is not paired. Import a CA signed Certificate for CSR.
The password you entered is incorrect. Private key password is entered accidentally when importing User Certificate. Re-enter the correct password.
The port number must be between 0 and 65535. Full-width alphanumeric character or values not specified is entered. Re-enter the correct value.

KEY POINTS


When error occurred with selecting multiple Controllers during the process of application, the error will be displayed in processing dialog.