Errors of Controllers
Following shows error messages and solutions of Controller regarding OPC UA Server.
| No. | Message | Remedy |
|---|---|---|
| 7930 | OPC UA Server. Not Activated. | Activate the OPC UA function. |
| 7931 | OPC UA Server. Certificate not configured. | Register a Sever Certificate. Or reconsider the using type of the Server Certificate. |
| 7932 | OPC UA Server. Invalid parameter. | Reconsider the setting of the Server. |
| 7933 | OPC UA Server. Port number conflicts. | Change the port number. |
| 580 | OPC UA Server. Server error. | Reboot the Controller. |
| 581 | OPC UA Server. Server log is activated. | Turn OFF the log function of OPC UA Server. Reboot the Controller. |
| 582 | OPC UA Server. File size of the server log is exceeded. | Turn OFF the log function of OPC UA Server. Reboot the Controller. |
KEY POINTS
There is no description for Controller errors elated to sensor data acquisition. For more information about errors or warnings related to sensor data, refer to following.
Specifications of Force Sensor Node - ErrorStatus Node