Decoupling of Moving Devices
If several moving devices are mounted close to each other in parallel, it is necessary to "decouple the vibrations" to prevent the motion of one device from being affected by the motion of others.
It is recommended that each device be equipped with a separate base table to prevent vibrational interference. If this is not possible, you can use parts that have antivibration technology to isolate vibrations (e.g. vibration isolators).
KEY POINTS
The vibration isolator solution is only applicable to IF-240, 380 and 530.
Symbols | Meaning |
---|---|
a | vibration isolator |
For the mass [M] and dimensions [A × B] of the base table, refer to the following:
For the vibration isolators, refer to the following:
KEY POINTS
Increasing the mass of the base table to avoid using vibration isolators does not ensure that other devices can completely avoid the effect of vibrations.