AC Power Cable
WARNING
- All work operations should be performed by people with specialized knowledge and skills in the field.
- The ground wire (green/yellow) of the AC power cable must be connected to the ground terminal of the power distribution system. If the ground wire is improperly connected to ground, it may result in the electric shock.
- Always use a power plug or a disconnecting device for the power connection cable. Never connect the Controller directly to the factory power supply.
- Select a plug or disconnecting device which complies with the safety standards of the respective country.
- When connecting to a transformer, connect the N and PE terminals of the AC power cable to the neutral terminal of the transformer.
When connecting the plug of the AC power cable to the Controller, insert until it clicks into place as shown in the figure below.
Connect the power supply as shown in the table below.
Identification Label | Connection Point |
---|---|
N | Neutral |
L | Live |
PE | Protective earth |
Specifications
Item | Specifications |
---|---|
Cable length | 3 m |
Wire diameter | AWG 14 / 2.5 mm2 |
Terminal | M4 round terminal |
Recommended tightening torque | 1.2 N·m * |
*: The tightening torque should be determined after checking the specifications of the plug to be used.