Editing the Maintenance Information
This section describes the procedure for editing the Maintenance information that was set.
From the Epson RC+ menu, select [Tools] - [Controller] to display the [Controller Tools] dialog box.
To edit the Maintenance information, open the [Maintenance] dialog box.
Select a common or specified axis from the tree to display information on the target part.
Select the alarm to be changed, and click the [Change] button.
Open the [Change Alarm] dialog box, and enter one of the following dates.
- Date grease was applied
- Date timing belt purchased or replaced
- Date motor purchased or replaced
- Date reduction gear purchased or replaced
- Date ball screw spline purchased or replaced
Click the [OK] button to change the specified alarm information.
KEY POINTS
An offset can be set for the wear rate of an existing part.
The following calculations should be used as a guideline for setting the offset.
Measures the number of available months for past operations using the "HealthRBAnalysis" command.
Check the past motor power-on time in the status save viewer.
The following formula is used to calculate the approximate offset.
For details, refer to the following manual.
"Epson RC+ SPEL+ Language Reference"