General differences of EPSON RC+ 5.0 and EPSON RC+ 7.0 or Epson RC+ 8.0 are as follows.

Item EPSON RC+ 7.0 and Epson RC+ 8.0 EPSON RC+ 5.0
Number of task Up to 32 tasks (Background task : Up to 16 tasks) Up to 16 tasks
Type of task

Able to specify NoPouse task

Able to specify NoEmgAbort task

Able to specify Background task

Able to specify NoPouse task

Able to specify NoEmgAbort task

Special TRAP such as TRAP ERROR Supported Not supported
Task starts by TRAP number Dedicated task number Dedicated task number
Multi Manipulator Supported Not supported
Robot number 1 to 16 1
Number of significant figure for Real type 6 digits 6 digits
Number of significant figure for Double type 14 digits 14 digits
Array elements number

Other than string variable

Local variable 2,000

Global variable 100,000

Module variable 100,000

Global Preserve variable 4,000

Other than string variable

Local variable 1,000

Global variable 10,000

Module variable 10,000

Global Preserve variable 1,000

String variable

Local variable 200

Global variable 10,000

Module variable 10,000

Global Preserve variable 400

String variable

Local variable 100

Global variable 1,000

Module variable 1,000

Global Preserve variable 100

Device number

21:PC

22:REMOTE

24:TP

20:TP3

21:PC

22:REMOTE

23:OP

24:TP

Control device

Remote I/O

PC

REMOTE COM

REMOTE Ethernet

TP3

Remote I/O

PC

OP1

REMOTE Ethernet

Timer number range 0 to 63 0 to 15
Program capacity 8 MB 4 MB
Signal No range for SyncLock, SyncUnlock 0 to 63 0 to 15
Signal No range for WaitSig, Signal 0 to 63 0 to 5
Memory I/O port 1024 256
I/O port number Common with EPSON RC+ 5.0
Port No of Ethernet 201 to 216 201 to 208
Remote I/O assignment Assigned as default Assigned as default
Port No of RS-232C communication 1 to 8, 1001 to 1008 1 to 8
OpenCom execution of RS-232C communication port Mandatory Mandatory
Input/output to files Supported Not supported
File number 30 to 63 Not supported
Access number for the database 501 to 508 Not supported
Vision Guide

Network camera type

Frame grubber type

Network camera type
Conveyor tracking Supported Not supported
PG robot Supported Not supported
OCR Supported Not supported
Security Supported Not supported
VBGuide 5.0 (RC+ API 7.0) Supported VBGuide Lite is supported
Fieldbus I/O Use normal I/O commands Use normal I/O commands
Fieldbus master Response is not guaranteed Not supported
Fieldbus slave Response is guaranteed Response is guaranteed
GUI Builder Supported Not supported
Error number Common with EPSON RC+ 5.0