LS8-C

Standard environment specification (LS8-C*02S)

Symbol Description
a Joint #3 #4 Brake release switch
b LED lamp
c Arm #2
d Shaft
e Arm #1

Symbol Description
a Signature label (Serial No. of Manipulator)
b User connector (15 pin D-sub)
c Blue (Fittings for ⌀4 mm pneumatic tube)
d Blue (Fittings for ⌀6 mm pneumatic tube)
e Power cable
f Signal Cable
g White (Fittings for ⌀6 mm pneumatic tube)
h Ethernet connector

KEY POINTS


  • The brake release switch affects both Joints #3 and #4. When the brake release switch is pressed in emergency mode, the brake for both Joints #3 and #4 are released simultaneously.
  • While the LED lamp is on, current is being applied to the Manipulator. Performing any work with the power ON is extremely hazardous and may result in electric shock and/or malfunction of the robot system. Make sure to turn OFF the controller power before maintenance work.

Standard environment specification (LS8-C*02S)

If you are to install objects that may interfere with the robot, make sure to obtain enough clearance from the dimensions described below:

LS8-C502S LS8-C602S LS8-C702S
a 225 325 425
b 560 590 620

Cleanroom+ESD Specification (LS8-C*02C)

The appearance of the cleanroom + ESD specification differs from the standard environment specification in the following parts:

Symbol Description
a Upper bellows
b Lower bellows
d Plating cover (Anti-static)
c Exhaust port

Cleanroom+ESD Specification (LS8-C*02C)

If you are to install objects that may interfere with the robot, make sure to obtain enough clearance from the dimensions described below:

LS8-C502C LS8-C602C LS8-C702C
a 225 325 425
b 560 590 620