PF_Abort
Forces the Part Feeding process to stop for the specified part.
Syntax
PF_Abort part ID
Parameters
- Part ID
Specify the part ID. (Use an integer from 1 to 32.)
Return values
None
Description
Immediately aborts the Part Feeding process for the specified part.
Unlike PF_Stop, this aborts the callback function in progress.
PF_Abort can be executed to stop platform and hopper vibrations even when the Part Feeding process has not been started using PF_Start.
When operating in multi-part, any PartID set in PF_Start can be specified.
Cannot be executed from a virtual controller or command window.
Examples
PF_Abort 1