Restoring the Default IP Address
The following procedure explains how to reboot the feeder so that it uses the default IP address, subnet mask and TCP port number. Perform this operation when the IP address, subnet mask and TCP port number are unknown and you cannot connect to the part feeder.
Switch off the power. Or disconnect the power cable.
Insert a tip in the [Reset IP] hole, then either turn the power back on, or reconnect the part feeder to the power source.
The part feeder will now use the following default parameters at startup:
- IP Address: 192.168.0.64
- SubnetMask: 255.255.255.0
- TCP Port: 4001
Symbols | Meaning |
---|---|
a | [Reset IP] hole |
You can use Epson RC+ to modify these parameters as you wish.
For more details, refer to following:
"Epson RC+ 8.0 Option Part Feeding 8.0 Introduction & Software - System Configuration"