Replacing the Purging Actuator
CAUTION
Before replacing the actuator, unplug the purging frame from the feeder and remove it. (Four hand-tightened screws)
Remove the protective cover.
4 screws Tx10
Symbols | Meaning |
---|---|
a | Protective cover |
Cut the zip-tie, taking care not to damage the cables.
Unscrew the actuator block.
3 screws Tx10
Remove the actuator and disconnect it by pulling on the connector, not on the cable itself.
Symbols | Meaning |
---|---|
a | Actuator |
Remove the retaining ring.
Swap out the actuator block.
Reattach the retaining ring.
Symbols | Meaning |
---|---|
a | Retaining ring |
b | Actuator |
Plug in the actuator block (1).
Tighten the flap screw (2). (hold the flap in the closed position while screwing in)
Screw in the bracket (3) with the flap still in held in the closed position.
3 screws Tx 10, 1.2Nm
Symbols | Meaning |
---|---|
a | Actuator |
Tie the cables together with a zip-tie.
Screw the protective cover back into position.
4 screws Tx 10, 0.6 Nm
Symbols | Meaning |
---|---|
a | Protective cover |