Calibration & Test
In the tree, click "Calibration".
Then, click the [Calibrate & Test] button.
The [Calibrate & Test] wizard starts.
Select [Part Area] tab.
Put one part in the center of the platform.
Click the [Run] button.
The next message is displayed.
Click the [Yes] button.
Check the value displayed in the "Part Area".
Click the [Apply] button.
KEY POINTS
Following both Calibration (8) [Flip & Separate] and (14) [Region] are not necessary but recommend running calibration.
Select [Flip & Separation] tab.
Put the same number of parts that are displayed on the platform.
Click the [Run] button.
The next message is displayed.
Click the [Yes] button.
After running feeder vibration and vision processing several times, check to confirm that each value in [Results] has been updated.
Click the [Apply] button.
Select [Region] tab.
Change the number of input parts to one.
Next message displayed.
Click the [Run] button.
After running feeder vibration and vision processing several times, check to confirm that each value in [Results] has been updated.
Click the [Apply] button.