Alarm Notification Procedure

When the recommended replacement interval or recommended greasing interval is reached for any part, the Controller enters a warning state and displays a warning message.
For details, refer to the following manual.
"Status Code/Error Code List"

One method of alarm notification is to set the alarm to an output bit of the remote I/O.
Remote I/O can be set from [Setup] - [System Configuration] - [Controller] - [Remote Control] in Epson RC+.
For details, refer to the following manual.
"Epson RC+ User's Guide - Remote I/O"


KEY POINTS


  • If an alarm occurs, the Controller enters a warning state.
  • Alarm1 to Alarm9, which are set to the output bits of the remote I/O, monitor the occurrence of warnings in five-minute cycles.
  • The timing of alarm occurrence and their output at the Controller is different. The alarm may be output to the remote I/O up to 5 minutes after the alarm has occurred at the Controller.