Sequence
A sequence can register the order (sequence) in which movement actions, output movements, and opening and closing of the purge gate are executed. You can register up to seven actions in a single sequence. You can set up to 25 sequences on a single feeder.
| Type | Operation | Duration mode | Custom value |
|---|---|---|---|
| None | (Not available) | (Not available) | (Not available) |
| Movement action | Actions A to Z | [Custom] or [Original] | Operation time: 100 to 30000 [ms] |
| Output movement | Hopper 1/Hopper 2 | [Custom] or [Original] | Operation time: 100 to 30000 [ms] |
| Purge gate | Open/Close | (Not available) | (Not available) |
| Wait time | (Not available) | (Not available) | Wait time: 100 to 30000 [ms] |
You can choose between [Custom] or [Original] for the duration of the movement action and output.
- If you select [Custom]: The [Custom value] set on the sequence screen will be the duration.
- If you select [Original]: The duration set in the vibration settings will be used.
KEY POINTS
A sequence is independent and not associated with a part number. Therefore, the sequence you create will be executed using the currently set part number. Check the part number before running the sequence.
Furthermore, by intentionally switching between parts such as part 01 and part 02, a single sequence can be reused with multiple part numbers.