Configuring the Force Sensor Unit
From the tree, select [Controller]- [Force Sensor]-[Sensor*]. Configure the Force Sensor in [System Configuration].
Item | Description |
---|---|
Serial | This is the serial number of the Force Sensor. (up to 10 characters) |
Enabled | Set the use of the Force Sensor. Checkbox selected: Gets the force information from the sensor. |
Name | Set the name of the Force Sensor. (up to 32 single-byte characters) |
Robot | Set the link of the Force Sensor with the added robot. Select the number of the robot to which the Force Sensor is connected. |
Description | The user can enter any comments. (up to 255 single-byte characters) |
Close | Close the [System Configuration] dialog. Restart the system if the settings are changed. |
Apply | Saves the changed values. |
Restore | Restores the original values. |
Force Sensor Connection Procedure
Connect the Force Sensor with the following procedure.
- When using the Force Sensor:
Connect the Robot Controller and the Force Sensor with a communication cable.
When using the Force Sensor board:
Mount the Force Sensor board on the option slot of the Robot Controller. - Connect the Force Sensor and the Force Sensor or board with a Force Sensor cable and a Force Sensor M/I cable.
- When using the Force Sensor:
Turn ON the Force Sensor. - Turn ON the Robot Controller.
- Start Epson RC+ 8.0 and establish a connection with the Robot Controller.
- From the Setup menu, select [System Configuration].
The [System Configuration] dialog box is displayed. - From the tree, select [Controller]-[Force Sensor]-[Sensor 1].
(Select the number of the sensor port of the Force Sensor to which the Force Sensor is connected.)
- In [Robot], set the number of the robot to which the Force Sensor is mounted.
- To apply the changes to the settings, click the [Apply] button.
To cancel the changes, click the [Restore] button. - Click the [Close] button.
Clicking the button restarts the system and applies the changes to the settings.
Force Sensor Disconnection Procedure
Disconnect the Force Sensor with the following procedure.
- Start Epson RC+ 8.0 and establish a connection with the Robot Controller.
- From the Setup menu, select [System Configuration].
- From the tree, click [Controller]- [Force Sensor]- [Sensor 1].
(Select the number of the sensor port of the Force Sensor to which the Force Sensor is connected.) - Unselect the [Enabled] checkbox.
- Click the [Apply] button.
- Click the [Close] button.
The robot controller restarts and the changes to the settings are applied. - Turn OFF the Robot Controller.
- Disconnect the Force Sensor from the Force Sensor board.
Force Sensor Replacement Procedure
Replace the Force Sensor with the following procedure.
- Refer to "Force Sensor Disconnection Procedure" described above and disconnect the Force Sensor.
- Refer to "Force Sensor Connection Procedure" described above and connect a new Force Sensor.