Configuring the Force Sensor Unit

From the tree, select [Controller]- [Force Sensor]-[Sensor*]. Configure the Force Sensor in [System Configuration].
image

Item
Description
Serial This is the serial number of the Force Sensor. (up to 10 characters)
Enabled

Set the use of the Force Sensor.

Checkbox selected: Gets the force information from the sensor.

Name Set the name of the Force Sensor. (up to 32 single-byte characters)
Robot

Set the link of the Force Sensor with the added robot.

Select the number of the robot to which the Force Sensor is connected.

Description The user can enter any comments. (up to 255 single-byte characters)
Close

Close the [System Configuration] dialog.

Restart the system if the settings are changed.

Apply Saves the changed values.
Restore Restores the original values.

Force Sensor Connection Procedure

Connect the Force Sensor with the following procedure.

  1. When using the Force Sensor:
    Connect the Robot Controller and the Force Sensor with a communication cable.
    When using the Force Sensor board:
    Mount the Force Sensor board on the option slot of the Robot Controller.
  2. Connect the Force Sensor and the Force Sensor or board with a Force Sensor cable and a Force Sensor M/I cable.
  3. When using the Force Sensor:
    Turn ON the Force Sensor.
  4. Turn ON the Robot Controller.
  5. Start Epson RC+ 8.0 and establish a connection with the Robot Controller.
  6. From the Setup menu, select [System Configuration].
    The [System Configuration] dialog box is displayed.
  7. From the tree, select [Controller]-[Force Sensor]-[Sensor 1].
    (Select the number of the sensor port of the Force Sensor to which the Force Sensor is connected.)
    image
  8. In [Robot], set the number of the robot to which the Force Sensor is mounted.
  9. To apply the changes to the settings, click the [Apply] button.
    To cancel the changes, click the [Restore] button.
  10. Click the [Close] button.
    Clicking the button restarts the system and applies the changes to the settings.

Force Sensor Disconnection Procedure

Disconnect the Force Sensor with the following procedure.

  1. Start Epson RC+ 8.0 and establish a connection with the Robot Controller.
  2. From the Setup menu, select [System Configuration].
  3. From the tree, click [Controller]- [Force Sensor]- [Sensor 1].
    (Select the number of the sensor port of the Force Sensor to which the Force Sensor is connected.)
  4. Unselect the [Enabled] checkbox.
  5. Click the [Apply] button.
  6. Click the [Close] button.
    The robot controller restarts and the changes to the settings are applied.
  7. Turn OFF the Robot Controller.
  8. Disconnect the Force Sensor from the Force Sensor board.

Force Sensor Replacement Procedure

Replace the Force Sensor with the following procedure.

  1. Refer to "Force Sensor Disconnection Procedure" described above and disconnect the Force Sensor.
  2. Refer to "Force Sensor Connection Procedure" described above and connect a new Force Sensor.