Strength of the Ball Screw Spline
If a load exceeding the allowable value is applied to the ball screw spline, it may not work properly due to deformation or breakage of the shaft.
If a load exceeding the allowable value is applied to the ball screw spline, the ball screw spline unit must be replaced.
The allowable load varies depending on the distance over which the load is applied. For calculating the allowable load, see the calculation formula below.
| Symbol | Description |
|---|---|
| a | End of the spline nut |
Allowable bending moment
LA3-A: M=13,000 N∙mm
LA6-A: M=27,000 N∙mm
Moment
M=F·L=100·100=10,000 N·mm
Example:
If 100 N (10.2kgf) load is applied at 100 mm from the end of the spline nut