Max. Pulse Range of Joint #3
The 0 (zero) pulse position of Joint #3 is the position where the shaft is at its upper limit. The pulse value is always negative because Joint #3 always moves lower than the 0 pulse position.
| Symbol | Description |
|---|---|
| a | Upper limit: 0 pulse |
| Model number | Joint #3 stroke | Lower Limit Pulse |
|---|---|---|
| LS50-CA04S | 400 mm | -806597 pulse |
| LS50-CA02S | 210 mm | -423464 pulse |