ECP Statement
Selects or displays the current ECP (external control point).
Syntax
(1) ECP ECPNumber
(2) ECP
Parameters
- ECP Number
- Optional. Integer expression from 0 to 15 representing which of 16 ECP definitions to use with subsequent motion instructions. ECP 0 makes the ECP selection invalid.
Return Values
Displays current ECP when used without parameters.
Description
ECP selects the external control point specified by the ECPnumber (ECPNumber).
Note
This command will only work if the External Control Point option is active.
Power Off and Its Effect on the ECP Selection
Turning main power off clears the ECP selection.
See Also
ECPSet
ECP Statement Example
>ecpset 1, 100, 200, 0, 0
>ecp 1