FF_ReadSequence

Reads the sequence parameters from the feeder flash memory using the specified sequence ID and operation number.

Format

FF_ReadSequence Operation number, Sequence ID

Parameter

  • Operation number
    • 1 to 7: Specifies the operation number.
  • Sequence ID
    • 1 to 26: Specifies the sequence ID.

Returned value

Element order Description
1 Operation number (same as value specified in parameter)
2 Type
  • 0: None
  • 1: Platform Vibration
  • 2: Output Activation
  • 3: Waiting Time
  • 4: Purge Gate
3 Operation
  • A to Z: Platform Vibration or Output Activation action
  • 0/1: Purge gate status (0: Closed/1: Open)
4 Continuation mode
  • 0 (Fixed)
5 Duration
  • 0 to 30000 [ms]
6 PartCntMax (not used, so "0" always returned)
7 Sequence ID (same as value specified in parameter)

Example of use

Read the sequence parameters for sequence ID "3" and operation number "2".

The returned values are delimited by commas.

> FF_ReadSequence 2, 3
2, 1, C, 0, 1000, 0, 3