FF_CurrentState Function

Acquires the internal temperature, voltage and current status of the feeder.

Format

FF_CurrentState Setting values

Parameter

  • Setting value: Specifies the value to acquire.
    • FC_TEMP: Acquires the internal temperature of the feeder.
    • FC_INTVOLT: Acquires the input voltage.
    • FC_INTCURENT: Acquires the input current.

Returned value

Setting value Returned value
FC_TEMP
  • Element 1: Motor drive temperature (in 0.1°C increments)
FC_INTVOLT
  • Element 1: Power1 input voltage (0 to 65535, 0.1 V increments)
  • Element 2: Power2 available (0: No/1: Yes)
FC_INTCURENT
  • Element 1: Power1 input current (0 to 65535, 0.1 A increments)
  • Element 2: Power2 input current (0 to 65535, 0.1 A increments)
  • Element 3: Motor 1 input current (0 to 65535, 0.1 A increments)
  • Element 4: Motor 2 input current (0 to 65535, 0.1 A increments)
  • Element 5: Motor 3 input current (0 to 65535, 0.1 A increments)
  • Element 6: Motor 4 input current (0 to 65535, 0.1 A increments)

Example of use

Acquire the internal temperature of the feeder.

The returned value "425" indicates that the internal temperature is 42.5°C.

> FF_CurrentState FC_TEMP
425

Acquire the input voltage.

The first returned element "243" indicates 24.3 V. The second returned element "1" indicates that Power2 is present.

> FF_CurrentState FC_INTVOLT
243, 1

Acquire the input current.

The Power1 (5.2 A), Power2 (2.3 A), Motor 1 (2.5 A), Motor 2 (2.5 A), Motor 3 (2.6 A), and Motor 4 (2.5 A) current values are shown in order.

> FF_CurrentState FC_INTCURRENT
52, 23, 25, 25, 26, 25