Master: Uninitialized Network

Master Unit LED Error Description
BF ST
Light OFF Light OFF Uninitialized network Master unit power error

Master unit configuration error

Process Flowchart

Causes of Error

Possible Cause Examination Method Countermeasure
Electrical surges of master device power supply Measure voltage of the device power supply at the master unit.

→ It should be within the range of sufficient voltage for device operation.

Check voltage of the device power supply.
Master device configuration error Check that the master device was configured properly.

→ After changing the configuration, verify whether the problem is fixed.

Check the master unit configuration.
Broken master unit Replace the broken master unit with a new one.

→ Verify whether the problem is fixed.

Replace the master unit with a new one.