Master: Configuration Error
| Master Unit LED | Error | Description | |
|---|---|---|---|
| BF | ST | ||
| Red Light ON | - | Physical error | Nonstandard wiring Signal wire connection failure Signal wire short circuit |
Process Flowchart
* See also:
| Symbol | See also: |
|---|---|
| 1 | Disconnected Terminating Resistors, Cable Disconnection, Disconnected Connector, and Disconnected Signal Wire |
| 2 | Loose Connector and Signal Wire |
Causes of Error
| Possible Cause | Examination Method | Countermeasure |
|---|---|---|
|
| Fix the problem. How to find the trouble point: Remove the terminating resistor on one end of the network. The trouble point is where resistance changes from 220 Ω. |
| Check for the connection of connectors and signal wires. → The connectors and signal wires should be firmly connected.
| Connect the connectors and signal wires again. |
| Broken unit | Replace the trouble unit with a new one. → Verify whether the problem is fixed. | Replace the unit with a new one. |
| No cause is identified. | Identify the trouble point by dividing the network. → See also: Broken Unit Examination (Dividing Network Examination) | - |