Camera Searching by CV1/CV2
You may not be able to use Camera searching in VT series Manipulator if CV1/CV2 is used and the following two conditions are met.
- When connecting PC and VT series Manipulator with a USB
- When the configuration of a default gateway of VT series Manipulator is None or “0.0.0.0”
Type the IP address for CV1/ CV2 manually when you cannot use Camera searching.
For more details of Camera searching, refer to the following.
“Vision Guide 8.0 Hardware & Setup - Setup - CV1/CV2 Camera Configuration”