Code Number 1 ~

No. Message Countermeasure Note 1 Note 2

Error

Solution

1 The main system of the controller has started. - - -
2 Shutdown process has started due to a drop in the power supply voltage. - - -
3 The main system of the controller has shut down. This log is stored when the controller is rebooted from Epson RC+ or TP1. - -
4 Preserve variables save area has been cleaned. - - -
5 Function Main started. - - -
6 Function Main started. Logging this event to system history will be skipped because the count limit is over. - - -
7 Serial number conflict has been corrected. - - -
8 System backup has been executed. - - -
9 System restore has been executed. - - -
10 Robot parameters have been initialized. - - -
11 Offset pulse value between the encoder origin and home sensor (HOFS) has been changed. - Value after change Value before change -
17 Message saving mode has activated. - - -
18 Robot parameter file has been converted. - - -
20 Enable setting in TEACH mode has been saved. - - -
21 Enable setting in TEACH mode has been changed. - - -
23 EStop has activated. - Robot number executing motion command Controller status -
24 Safeguard has activated. - Robot number executing motion command Controller status -
25 Robot setting has been changed. -

1: Added new

2: Changed

3: Deleted

Robot number -
26 Alarm setting has been changed. - Alarm number - -
27 Safety Board has issued a Main stop signal. If an unintended stop has occurred, check the Notes in the system history. For details on stop signal types, refer to the following section.

Details of Note Information

For Safety signal details - Switch - Axis - Location - Safety input channel - Deceleration error details, see the following section.

Details of Note Information

-
28 Safety Board has issued a Sub stop signal. If an unintended stop has occurred, check the Notes in the system history. For details on stop signal types, refer to the following section.

Details of Note Information

For Safety signal details - Switch - Axis - Location - Safety input channel - Deceleration error details, see the following section.

Details of Note Information

-
50 The battery alarm for the controller has been reset. - - -
51 The battery alarm for the robot has been reset. - Robot number - -
52 The grease alarm for the robot has been reset. - Robot number - -
100 Device has connected to Controller. - - -
101 Console device has been changed. - - -
104 Cooperative mode has been changed. - 0: Independent

1: Cooperative

- -
110 Controller firmware has been installed. - 1: Setup

2: Initialization

3: Version upgrade

4: Restore

- -
111 IP address has been restored. - - -
112 Controller rebooted. - - -
113 Communication recovered from busy status. - 1: Ethernet

2: USB

- -
120 Epson RC+ connected to the controller. - 1: Ethernet

2: USB

- -
121 TP connected to the controller. - - -
123 Epson RC+ disconnected from the Controller. - - -
124 TP disconnected from the controller. - - -
126 Working mode changed to AUTO. - - -
127 Working mode changed to Program. - - -
128 Working mode changed to TEACH. - - -
129 Remote Ethernet connected to the controller. - - -
130 Remote Ethernet disconnected to the controller. - - -
133 Working mode changed to TEST. - - -
134 Epson RC+ Express Edition connected to the controller. - - -
135 Epson RC+ Express Edition disconnected from the controller. - - -
411 The battery alarm(L10) for the robot occurred. Do the following in order.

1. Replace the battery.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
412 The belt alarm(L10) occurred. Do the following in order.

1. Replace the belt.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
413 The grease alarm(L10) for the ball screw spline occurred. Do the following in order.

1. Grease the robot.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
414 The motor alarm(L10) occurred. Do the following in order.

1. Replace the motor.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
415 The gear alarm(L10) occurred. Replace the gear units and reset the alarm. Do the following in order.

1. Replace the gear units.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
416 The ball screw spline alarm(L10) occurred. Do the following in order.

1. Replace the ball screw spline.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
421 The battery alarm(L50) for the robot occurred. Do the following in order.

1. Replace the battery.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
422 The belt alarm(L50) occurred. Do the following in order.

1. Replace the belt.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
423 The grease alarm(L50) for the ball screw spline occurred. Do the following in order.

1. Grease the robot.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
424 The motor alarm(L50) occurred. Do the following in order.

1. Replace the motor.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
425 The gear alarm(L50) occurred. Do the following in order.

1. Replace the gear units.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
426 The ball screw spline alarm(L50) occurred. Do the following in order.

1. Replace the ball screw spline.

2. Reset the alarm in Epson RC+ - [Tools] - [Controller] - [Maintenance].

1000 times of consumption rate 1000 times of boundary value Reboot
501 Trace history is active. Effects system performance if trace history is active. - Reboot
502 Memory has been initialized. When this error occurs, the value of the Global Preserve variable will be initialized. Do one of the following and reboot the controller:

- Replace the MAIN board.

- After replacing the MAIN board, if the warning is displayed on the first startup, reboot the controller.

Magic number Size verification Reboot
504 An error occurred in a background task. Make sure there are no problems in the system and continue the operation. Task number 0 Reboot
505 Controller rebooted by auto recovery. Settings may have been reset, so check before performing the operation. - Reboot
511 Check the backup battery. Check the backup battery. 100 times of current value 100 times of boundary value Reboot
512 5V input voltage for the MAIN board is lower than the specified voltage. Replace the MAIN board. 100 times of current value 100 times of boundary value Reboot
513 24V input voltage for the motor brake, encoder, and fan is lower than the specified voltage. Do one of the following:

- Replace the MAIN board.

- Replace the PSU.

100 times of current value 100 times of boundary value Reboot
514 Internal temperature of the controller is higher than the specified temperature. Stop the controller as soon as possible and check whether the ambient temperature of the controller is not high. Check whether the filter is not clogged up. 100 times of current value 100 times of boundary value Reboot
515 Rotating speed of the controller fan is below the allowed speed (FAN1). Check whether the filter is not clogged up. Reboot the Controller. If the warning is not cleared, replace the fan. Current value Boundary value Reboot
516 Rotating speed of the controller fan is below the allowed speed (FAN2). Check whether the filter is not clogged up. Reboot the Controller. If the warning is not cleared, replace the fan. Current value Boundary value Reboot
517 Internal temperature of the controller is higher than the specified temperature. Stop the controller as soon as possible and check whether the ambient temperature of the controller is not high. Check whether the filter is not clogged up. 100 times of current value 100 times of boundary value Reboot
519 3.3V input voltage for the MAIN board is lower than the specified voltage. Replace the MAIN board. 100 times of current value 100 times of boundary value Reboot
520 DC input voltage for the MAIN board is outside the specified voltage range. Replace the MAIN board. 100 times of current value 100 times of boundary value Reboot
550 Communication with the Compact Vision is disconnected. Check the connection between the controller and compact vision. Camera No. - Reboot
551 Compact Vision CPU fan RPM has decreased. Check whether the fan filter of the compact vision is not clogged up. Reboot the controller and compact vision. If the warning is not cleared, replace the CPU fan. Camera No. Current value Reboot
552 Compact Vision CPU fan RPM has decreased. Replace the CPU fan of the compact vision. Camera No. Current value Reboot
553 Compact Vision chassis fan RPM has decreased. Check whether the fan filter of the compact vision is not clogged up. Reboot the controller and compact vision. If the warning is not cleared, replace the system fan. Camera No. Current value Reboot
554 Compact Vision chassis fan RPM has decreased. Replace the system fan of the compact vision. Camera No. Current value Reboot
555 Compact Vision CPU temperature is higher than the specified temperature. Check whether the fan filter of the compact vision is not clogged up. Reboot the controller and compact vision. If the warning is not cleared, check the compact vision installation environment (surrounding space, ambient temperature). Camera No. 100 times of current value Reboot
556 Compact Vision CPU temperature is higher than the specified temperature. Check whether the fan filter of the compact vision is not clogged up. Reboot the controller and compact vision. If the warning is not cleared, check the compact vision installation environment (surrounding space, ambient temperature). Camera No. 100 times of current value Reboot
557 Compact Vision backup battery voltage is lower than the specified temperature. Replace the compact vision backup battery. Camera No. 100 times of current value Reboot
558 Compact Vision backup battery voltage is lower than the specified temperature. Replace the compact vision backup battery. Camera No. 100 times of current value Reboot
559 Compact vision process was terminated abnormally. Reboot the controller and compact vision. Camera No. - Reboot
560 Compact Vision is out of memory. If the warning is not cleared, initialize the compact vision. Camera No. Current value Reboot
561 Compact Vision is out of disk space. Check the vision sequence if it has unnecessary models which can be reduced. Reduce the number of objects that use models (Geometric, Correlation, DefectFinder, etc.) Consider to use the USB memory. Camera No. Current value Reboot
562 A critical hardware error occurred in the Compact Vision unit. Check the hardware condition such as internal wiring. Reboot the controller and compact vision. If the warning is not cleared, initialize the compact vision. Camera No. - Reboot
563 A critical hardware error occurred in the Compact Vision unit. Check the hardware condition such as internal wiring. Reboot the controller and compact vision. If the warning is not cleared, replace the LED/SW board. Camera No. - Reboot
569 Communication with the compact vision recovered. If the warning is not cleared after the controller and compact vision are rebooted, replace the LED/SW board. Camera No. - Reboot
570 Compact Vision: Password authentication has failed. Enter the correct Compact Vision connection password in the RC+ Camera page. If the password is unknown, do one of the following:

- Set a new connection password in CV Monitor. Set the same password in the Epson RC+ Camera page.

- Perform a factory reset on the Compact Vision unit to clear the password. Rebuild the current RC+ project and check operation.

- Reboot
580 An error occurred in the OPC UA Server. Reboot the Controller. OPC UA Status Code (tens digit) - Reboot
581 OPC UA Server log is activated. 1. Turn OFF the log function of OPC UA Server.

2. Reboot the controller to enable settings.

- Reboot
582 OPC UA Server log size is exceeded. 1. Turn OFF the log function of OPC UA Server.

2. Reboot the controller to enable settings.

- Reboot
590 Detect the different of the calibration settings in the controller and Safety Board. Do one of the following and reboot the Controller:

- Calibrate in controller settings.

- Correct the settings of the Safety Board from the Safety Function Manager.

Axis number detected the difference at first. Pulse value of the axis detected the difference at first. Reboot
597 The PTP motion to avoid the singularity point has completed. Clicking the same jog button will operate the robot in the normal jog motion. - Reboot
598 Robot stopped due to collision detection. Move the manipulator to avoid collision. - Reboot
599 Jogging attempted near singularity point. Clicking the same jog button will operate the robot in the PTP motion. - Reboot
700 Motor driver type does not match the current robot model. Do one of the following:

- Check the robot model.

Replace the motor driver.

- -
701 Axis settings are duplicated with those of other robots (including PG). Check the robot model. - Reboot
702 Axis settings are duplicated with those of other robots (including PG). Check the robot model. - Reboot
703 Axis settings are duplicated with those of other robots (including PG). Check the robot model. - Reboot
704 Hardware information is undefined. Check the robot model. - -
736 The encoder was reset. Reboot the Controller. - -
737 The voltage of the encoder battery is low. Do one of the following:

- Turn the controller off and replace the battery. For the battery replacement procedure, refer to Maintenance in the Manipulator manual.

- Replace the MAIN board.

- Check the cable connection.

- -
752 Servo alarm D. Reboot the Controller. If this continues to occur, contact your dealer. - -