Minimizing Noise Interference
Follow guidelines listed below when connecting a PG board to a drive:
Minimize noise interference by using the wiring recommendations as described in the drive manual.
Use a noise filter on the primary power supply for EXTV/EXTVGND and separate between the primary and secondary wiring by at least 200mm.
For EXTV/EXTVGND and the instruction signals for using twisted pair (as indicated in the circuit diagram in the previous “Input and Output Circuits”), be sure to use twisted pair cables.
Use shielded twisted pair cable for connecting the PG board to the drive. Follow the drive manual and the manufacturer’s instructions for shielding.
Keep the wiring between the PG board and drive as short as possible (within 1.5 m) and position them to be separated from possible noise sources as much as possible.
For the load to be used in the controller’s (Control Unit’s) I/O, whether a relay or solenoid, make sure to use one with surge suppressor. Install a diode (or such) on the Load L side where there is no surge suppressor.
For such peripheral equipment as a conveyor, switching the rotating direction (start, forward, reverse) of an AC motor (an induction motor, a 3-phase induction motor, etc.) requires an appropriate spark suppressor between lines. The closer the suppressor is to the motor, the more effective the noise suppression.