PG Board Connector Pin Outs

The pin outs for the PG board connector (DX10A-100S) are shown in the following table.

For details of each signal, refer to the following.

Signal Functions

If you are using the optional cable, refer to the following later in this chapter.

PG Terminal Block Pin Outs

Pin Dir Signal Description
1 In CWLM1 CW limit signal for Axis #1 (*2)
2 In CCWLM1 CCW limit signal for Axis #1 (*2)
3 In NORG1 Near-to-origin signal for Axis #1
4 In ORG1 Origin signal for Axis #1 (*1)
5 In CWLM2 CW limit signal for Axis #2 (*2)
6 In CCWLM2 CCW limit signal for Axis #2 (*2)
7 In NORG2 Near-to-origin signal for Axis #2
8 In ORG2 Origin signal for Axis #2 (*1)
9 Not used
10 In ALM1 Alarm input signal for Axis #1
11 In ALM2 Alarm input signal for Axis #2
12 In ALM3 Alarm input signal for Axis #3
13 In ALM4 Alarm input signal for Axis #4
14 In EXTV External power supply for Input circuit
15 In EXTV External power supply for Input circuit
16 Out +COM CWP1, CCWP1 +COMMON
17 Out CWP1 CW pulse output signal for Axis #1
18 Out CWP1 Inverted CW pulse output for Axis #1
19 Out CCWP1 CCW pulse output for Axis #1
20 Out CCWP1 Inverted CCW pulse output for Axis #1
21 Out +DRSTCOM1 DRST1 + COMMON
22 Out DRST1 Drive Reset signal for Axis #1
23 In DEND1 Detection End signal for Axis #1
24 Not used
25 Not used
26 Not used
27 Not used
28 Not used
29 In +ZORG1 Encoder Phase +Z signal for Axis #1
30 In -ZORG1 Encoder Phase -Z signal for Axis #1
31 Not used
32 Out +COM CWP2, CCWP2 +COMMON
33 Out CWP2 CW pulse output signal for Axis #2
34 Out CWP2 Inverted CW pulse output for Axis #2
35 Out CCWP2 CCW pulse output for Axis #2
36 Out CCWP2 Inverted CCW pulse output for Axis #2
37 Out +DRSTCOM2 DRST2 + COMMON
38 Out DRST2 Drive Reset signal for Axis #2
39 In DEND2 Detection End signal for Axis #2
40 Not used
41 Not used
42 Not used
43 Not used
44 Not used
45 In +ZORG2 Encoder Phase +Z signal for Axis #2
46 In -ZORG2 Encoder Phase -Z signal for Axis #2
47 Not used
48 Not used
49 Not used
50 GND Ground
51 In CWLM3 CW limit signal for Axis #3 (*2)
52 In CCWLM3 CCW limit signal for Axis #3 (*2)
53 In NORG3 Near-to-origin signal for Axis #3
54 In ORG3 Origin signal for Axis #3 (1)
55 In CWLM4 CW limit signal for Axis #4 (*2)
56 In CCWLM4 CCW limit signal for Axis #4 (*2)
57 In NORG4 Near-to-origin signal for Axis #4
58 In ORG4 Origin signal for Axis #4 (1)
59 Not used
60 Out SVON1 Servo ON output signal for Axis #1
61 Out SVON2 Servo ON output signal for Axis #2
62 Out SVON3 Servo ON output signal for Axis #3
63 Out SVON4 Servo ON output signal for Axis #4
64 In EXTVGND External power supply GND for Input circuit
65 In EXTVGND External power supply GND for Input circuit
66 Out +COM CWP3, CCWP3 +COMMON
67 Out CWP3 CW pulse output signal for Axis #3
68 Out CWP3 Inverted CW pulse output for Axis #3
69 Out CCWP3 CCW pulse output for Axis #3
70 Out CCWP3 Inverted CCW pulse output for Axis #3
71 Out +DRSTCOM3 DRST3 + COMMON
72 Out DRST3 Drive Reset signal for Axis #3
73 In DEND3 Detection End signal for Axis #3
74 Not used
75 Not used
76 Not used
77 Not used
78 Not used
79 In +ZORG3 Encoder Phase +Z signal for Axis #3
80 In -ZORG3 Encoder Phase -Z signal for Axis #3
81 Not used
82 Out +COM CWP4, CCWP4 +COMMON
83 Out CWP4 CW pulse output signal for Axis #4
84 Out CWP4 Inverted CW pulse output for Axis #4
85 Out CCWP4 CCW pulse output for Axis #4
86 Out CCWP4 Inverted CCW pulse output for Axis #4
87 Out +DRSTCOM4 DRST4+ COMMON
88 Out DRST4 Drive Reset signal for Axis #4
89 In DEND4 Detection End signal for Axis #4
90 Not used
91 Not used
92 Not used
93 Not used
94 Not used
95 In +ZORG4 Encoder Phase +Z signal for Axis #4
96 In -ZORG4 Encoder Phase -Z signal for Axis #4
97 Not used
98 Not used
99 Not used
100 GND Ground

*1: Leave this terminal disconnected if you use Encoder Z Phase signal as the origin signal when a servo motor is used.

*2: When the status of the limit signal is OFF (the photo coupler in the input circuit is OFF), the axis is deemed to be out of the Permissible Working Range and pulse generation will be stopped. Therefore, you must connect to an external power source so that the limit signal(s) will remain ON when your system configuration does not use limit signals.