Cnv_Fine Statement

Sets the value of Cnv_Fine for one conveyor.

Syntax
Cnv_Fine conveyorNumber [, fineValue]

Parameters

conveyorNumber
Specify the conveyor number as an integer (1-16).
fineValue
Specify the distance in real number (unit: mm) to determine the completion of tracking.
A value of 0 means that Cnv_Fine is not used. If omitted, the current Cnv_Fine setting is displayed.

Description
After confirming the tracking operation is complete, specify the distance from the part that is acceptable for the next command. When specifying “0”, the Cnv_Fine setting will not be used and the next command will be accepted when the motion command is complete. The default value of “0” mm is automatically set when the following conditions occur:

  • Conveyor is created.
  • Controller is started.

Note


This command will only work if the Conveyor Tracking option is active.


See Also
Cnv_Fine Function

Cnv_Fine Statement Example

Cnv_Fine 1, 5