Editing of Input / Output Size
You can change the input/output size of EtherCAT slave board. Change the input/output size as necessary.
Select [Setup] - [System Configuration] and display the [System Configuration] dialog box.
Select [Controller] - [Inputs / Outputs] - [Fieldbus Slave] - [General].
Change the settings of [Input Byte] and [Output Byte].
In this example, both of them are changed to "20" Bytes.
KEY POINTS
Cautions when connecting OMRON PLC and this option:
The input/output size has limitations.
Select any of 32 bytes, 64 bytes, 128 bytes, or 256 bytes for both [Input Bytes] and [Output Bytes].
[Input Bytes] and [Output Bytes] may have a different size.
Click [Apply].
Click [Close].
The following dialog box appears and the Controller automatically starts rebooting.Select [Setup] - [System Configuration] and display the [System Configuration] dialog box.
Select [Controller] - [Inputs / Outputs].
Confirm that the following items are displayed in "Fieldbus Slave".
Inputs: "512" - "512 + Changed number of input I/O (Bits)"
Outputs: "512" - "512 + Changed number of output I/O (Bits)"In this example, Input byte is 20 bytes (160 bits) and "512 - 671" is displayed in Inputs.
Also, Output byte is 20 bytes (160 bits) and "512 - 671" is displayed in Outputs.Click [Close].