Specification
| Item | Specification |
|---|---|
| Part Number | PROFIBUS-DP master board manufactured by molex |
| Modes | Master |
| Baud Rates | 9.6 kbps, 19.2 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1500 kbps, 3 Mbps, 6 Mbps,12 Mbps |
| Interface | 1 PROFIBUS port (EN 50 170) |
| Output Current Capacity | Maximum 150mA |
| Supported Devices | All DP Devices |
| Maximum Stations | 126 (32 per segment) |
| GDS support | Supported |
| PROFIBUS-DP Class 1 | Supported |
| PROFIBUS-DP Class 2 | Supported |
| Max. Input data size | 1024 bit (128 bytes) |
| Max. Output data size | 1024 bit (128 bytes) |
| Automatic Detection | Yes. Devices can be detected automatically. |