Specification
| Item | Specification | |
|---|---|---|
| Name | PROFIBUS-DP slave module | |
| Connection Method | Hybrid (token passing procedure and master-slave communication) | |
| Baud Rates | 9.6 k, 19.2 k, 45.45 k, 93.75 k, 187.5 k, 500 k, 1.5 M, 3 M, 6 M, 12 M (bps) | |
| Transfer Distance | Baud Rates | Cable Length |
| 12 Mbps | 100 m | |
| 6 Mbps | 100 m | |
| 3 Mbps | 100 m | |
| 1.5 Mbps | 200 m | |
| 500 kbps | 400 m | |
| 187.5 kbps | 1000 m | |
| 93.75 kbps | 1200 m | |
| 45.45 kbps | 1200 m | |
| 19.2 kbps | 1200 m | |
| 9.6 kbps | 1200 m | |
| Maximum Stations | 126 (including master unit and repeater) | |
| Data Length / Frame | 244 bytes | |
| Cable | 2-wire cables dedicated to PROFIBUS (2 wires for signal) | |
| Modes | Slave | |
| Interface | 1 PROFIBUS-DP port (EN 50170) | |
| Output Current Capacity | Maximum 100 mA | |
| Max. Input data size | 1952 bit (244 bytes) | |
| Max. Output data size | 1952 bit (244 bytes) | |