ShutDown Statement

Shuts down Epson RC+ and optionally shuts down or restarts Windows.

Syntax
ShutDown [mode] [, Forced]

Parameters

mode
Set the mode shown below with an integer value.

Constant Value Meaning
Mode omitted -1 Displays a dialog allowing the user to choose the shutdown option.
SHUTDOWN_ALL 0 Shuts down Epson RC+ and Windows.
SHUTDOWN_RESTART 1 Shuts down Epson RC+ and restarts Windows.
SHUTDOWN_EPSONRC 2 Shuts down Epson RC+.
Forced
Optional. Use to force a shutdown.

Description
Use ShutDown to shut down RC+ and optionally shutdown or reboot Windows from your program. You can force a shutdown by using the Forced parameter.

Note


If you shutdown with the Forced parameter while tasks are running, you could lose data. Be sure to save data before shutdown.

  • About the Controllers to use

    Shutdown Statement cannot be used with T/VT series.

  • When the controller configuration is set to “Cooperative mode” in virtual controller

    When the controller configuration is set to “Cooperative mode” in the virtual controller, the global Preserve variables will not be saved if ShutDown statement is executed. Do not use ShutDown statement if you need to save the global Preserve variables.


See Also
Restart

ShutDown Statement Example

ShutDown 0    ' Shutdown Epson RC+ and Windows