PV1 Camera Configuration

  1. Start the Epson RC+ 8.0.

  2. Select [System Configuration] from the Setup menu.

  3. Click [Vision]-[Cameras] from the tree.

  4. Click the [Add] button to add a camera.

    To search the cameras on the network, select “Search for a camera” and click [OK].
    The following dialog box appears if the camera is found on the network.
    Select the camera to add and click the [Add] button.

    If you have information of the camera required for setting such as IP address, select “Manually configure a camera”.

  5. Select the camera model and ID as necessary.
    For the GigE camera, select the ID after selecting the camera model. The ID is a serial number of the camera.

  6. If you changed settings after adding the camera, click the [Apply] button.

  7. Repeat steps (4) through (6) to add cameras.

KEY POINTS


Up to 16 cameras (8 CV2 cameras and 8 PV1 cameras) can be configured.

When starting more than one Epson RC+ 8.0 by one PC, PV1 camera is only available in the first session.

Item Description
Name This is the name of the camera. The maximum length is 16.
IP Address

This is the IP address of the GigE camera.

The details are described below.

Software Configuration

Type Sets the type of camera.
Model Sets the model of camera.
Add

Adds a camera.

It is also possible to search and add the cameras on the network.

Delete Delete the currently selected camera.
Apply

Set current values after changes have been made.

For CV2: When this button is clicked, RC+ attempts to connect with the camera to verify the IP address and determine the camera type.

Restore Revert back to the previous values.
Configure… Click this button to open the [Camera configuration] dialog box.
Reset

For CV2.

Resets the currently selected CV2. All project files are cleared and the CV2 is restarted. Restart takes approximately one minute.

Update Firmware…

For CV2.

Updates the CV2 firmware. For more details, refer to the following section.

Hardware - Updating CV2 Firmware