System Cameras and Project Cameras
Epson RC+ system cameras are configured in [Setup]-[System Configuration]-[Vision]. Epson RC+ project cameras are mapped to the system cameras
When a new project is created, the project cameras are mapped one on one with the current system cameras.
When a project is opened, Epson RC+ attempts to automatically map the project cameras with the current system cameras. For example, if project camera 1 matches system camera 2, then project camera 1 is mapped to system camera 2. You can view the project camera mapping in [Project]-[Properties]-[Vision].
If one or more project cameras cannot be mapped to system cameras during project open, a [Resolve Camera Configuration] dialog box is displayed that allows the user to copy the “project camera configuration” to the “system camera configuration”, or keep the current system camera configuration.
If the “Copy project camera configuration to system camera configuration” in the [Resolve Method] box is selected, then the project camera configuration is copied to the system camera configuration as shown below.
If the “Use the current system camera configuration” in the [Resolve Method] box is selected, then the current system cameras are not changed, as shown below.
For the system cameras in the [Resolve Camera Configuration] dialog box, you can change if a camera is virtual or not using the [Virtual] checkbox in the [System Cameras] grid.
For users that use multiple projects from one PC, the project cameras can be mapped to the system cameras in [Project]-[Properties]-[Vision].
For example, say there are two projects being used on the same PC: Project A and Project B. The projects have two system cameras. Project A project camera 1 uses system camera 1, and Project B project camera 1 uses system camera 2. In this way, both projects use project camera 1.