Setting Configure Switch
WARNING
Make sure that the power is turned OFF before installing/removing any boards or connecting/disconnecting any cables. Working with the power ON is extremely hazardous and may result in electric shock and/or malfunction of equipment.
Set the baud rates between the MAC address of the device and the master by setting the DeviceNet slave board configure switch.
Set the MAC address for DeviceNet slave board by setting the configure switch. Make sure that the MAC address is different from the other devices in the network. Refer to the following table for configuration.
MAC address Switch sw3 (MSB)
sw4 sw5 sw6 sw7 sw8 (LSB)
0 OFF OFF OFF OFF OFF OFF 1 OFF OFF OFF OFF OFF ON 2 OFF OFF OFF OFF ON OFF 3 OFF OFF OFF OFF ON ON ⋮ OFF OFF OFF OFF OFF OFF 62 ON ON ON ON ON OFF 63 (at shipment)
ON ON ON ON ON ON Set the DeviceNet slave baud rate. Check the master configuration and set the same baud rate. Refer to the following table for configuration.
Baud Rates Switch sw1 sw2 125 k OFF OFF 250 k OFF ON 500 k ON OFF Configuration prohibited ON ON