Setting Configure Switch
WARNING
Make sure that the power is turned OFF before installing/removing any boards or connecting/disconnecting any cables. Working with the power ON is extremely hazardous and may result in electric shock and/or malfunction of equipment.
Configuration of the device station is available with the station configure switch on the CC-Link slave board.
Baud rate configuration is available with baud rate configure switch on the CC-Link board.
Set the station of the CC-Link slave board with the station configuration switch.
Make sure that the station does not duplicate with the other devices inside the network at configuration.
Switches on the ×10 side are for tenths digit address value configuration. Switches on the ×1 side are for units digit address value configuration. Stations from 1 to 64 are available.Set the CC-Link baud rate. Check the master configuration and set the same baud rate. Refer to the following table for configuration.
Baud Rates Baud Rate Configure Switch 156 k 0 625 k 1 2.5 M 2 5 M 3 10 M 4 Configuration prohibited 5-9