Confirmation of Epson RC+ 8.0
When the CC-Link slave module is installed to the Controller, it is recognized automatically. Confirm that Epson RC+ 8.0 has recognized the module in the following procedure.
Select [Setup] - [System Configuration] and display the [System Configuration] dialog box.
Select [Controller] - [Inputs / Outputs].
Confirm that the following items are displayed in "Fieldbus slave".
Installed: Yes
Inputs: 512-767 (default setting)
Outputs: 512-767 (default setting)Select [Fieldbus Slave] - [General]
Set each item to the specific value to connect the CC-Link network.
For information about the setting values, contact your network administrator.Click [Close].
KEY POINTS
These is no Extended Cyclic Setting on CC-Link Ver1.10. If you change Version to 2.00, you can configure Extended Cyclic Setting.