Confirmation of Epson RC+ 8.0

When the CC-Link slave module is installed to the Controller, it is recognized automatically. Confirm that Epson RC+ 8.0 has recognized the module in the following procedure.

  1. Select [Setup] - [System Configuration] and display the [System Configuration] dialog box.

  2. Select [Controller] - [Inputs / Outputs].

  3. Confirm that the following items are displayed in "Fieldbus slave".
    Installed: Yes
    Inputs: 512-767 (default setting)
    Outputs: 512-767 (default setting)

  4. Select [Fieldbus Slave] - [General]

  5. Set each item to the specific value to connect the CC-Link network.
    For information about the setting values, contact your network administrator.

  6. Click [Close].

KEY POINTS


These is no Extended Cyclic Setting on CC-Link Ver1.10. If you change Version to 2.00, you can configure Extended Cyclic Setting.