Editing of Input / Output Size

You can change the input/output size of CC-Link slave board. Change the input/output size as necessary.

  1. Select [Setup] - [System Configuration] and display the [System Configuration] dialog box.

  2. Select [Controller] - [Inputs / Outputs] - [Fieldbus Slave] - [General].

  3. Change the settings of [Version] of CC-Link.
    In this example, Version is changed to "2.00".

  4. Change the settings of [Extended Cyclic Setting].
    In this example, Extended Cyclic Setting is changed to "2".

  5. Change the settings of [Input Byte] and [Output Byte].
    In this example, both of them are changed to "92" Bytes.

  6. Click [Apply].

  7. Click [Close].
    The following dialog box appears and the Controller automatically starts rebooting.

  8. Select [Setup] - [System Configuration] and display the [System Configuration] dialog box.

  9. Select [Controller] - [Inputs / Outputs].

  10. Confirm that the following items are displayed in "Fieldbus slave".
    Inputs: 512 - 1247
    Outputs: 512 - 1247
    In this example, Input byte is 92 bytes (736 bits) and 512-1247 is displayed in Inputs.
    Also, Output byte is 92 bytes (736 bits) and 512-1247 is displayed in Outputs.

  11. Click [Close].